     Series Solenoid Valve
     Regulating valve series
     Cut off the ball valve series
     Regulating valve series
     Butterfly Series
     Shut-off valve series
     Traps Series
     By valve series
     Accessories Series
     Steam solenoid valve
     Miniature solenoid valve
     Ultra-high temperature (HV) solenoid valve
     High pressure solenoid valve
     Corrosion resistant solenoid valve
     Signal solenoid valve
     Ultra-low-temperature solenoid valve
     Chase Drive solenoid valve
     Vacuum solenoid valve
     Gas solenoid valve
     Recurrent solenoid valve
     Liquids (gas) solenoid valve
     Fire solenoid valve
     Zero pressure activated solenoid valve
     Fountain solenoid valve
 
 
Your place: Index>> Maintenance
     Selection guide Solenoid Valve Selection knowledge    ◎ Selection of control valve knowledge     Maintenance


 

□ Use and maintenance:

1、Recommended to assign specific units responsible for the use and maintenance
2、1-2 annual meeting of the regular maintenance solenoid valve is reliable and the best way to longevity. Electromagnetic valve within the following four types of solenoid valve is impeding normal work and shorten the life of reasons.
   ⑴、Media use changes              
   ⑵、Rust inside receiver
   ⑶、Air compressor oil oxidized to produce carbon tar and other debris, mixed with pipeline 2.4Pipelines are dirt and other impurities in dust
3、Solenoid valve installed or again after a long time out to be put into operation leads to several media test action after normal work before the official
4、Valve steam again after a long time out and put into operation, should be discharged after examination condensed water moves several times, After normal working order and put into operation.
5、In the maintenance, the need to cut off power supply, shed medium pressure.
6、Coil not disassemble components
7、Disassemble for cleaning the solenoid valve may be used when kerosene `TCE, and other solutions. It should be noted, however rubber pieces may Swelling, Therefore it should change.
8、Unpick cleansing, according to the order of the components installed in restitution.
9、I have Fragile pieces of the company, when needed by the market, brochures explain.
10、Demolition order, fragile pieces, and other matters are not available between, to the headquarters of the Department of Technical Advisory(Advisory Hotline:0577-65021168
 

□ Installation notes:

1.Installation should carefully read the product's instruction manual to check whether or not the products fully comply with the requirement, the installation of familiar elements, make preparations.
2.Installed solenoid valve coils upward, and maintain the vertical position, the solenoid valve on the arrow or marking should be consistent with the pipeline flow, not installed in a splash of water or leaks place.
3.Before taking over with the pressure of 0.3MPa full irrigation channels, pipelines metal powder residue sealing material, Rust remove dirt, etc.; Solenoid Valve media should work without clean particle impurities valve installed before the proposed filters, Steam pipe installation traps; Electromagnetic valve on the surface of the dirt and filters, to regularly clean.
4.Electromagnetic valve in the event of malfunction, in order to prompt isolation solenoids, and ensure the normal operation, the best bypass device installed. Figure (1). When the solenoid valve installed in the slip road, solenoids than the diameter of the valve Road for a small-caliber figure (2) by-pass device. Note : Extension of the road to close the valve.
5.Do not install the valve in the pipeline low cavity to avoid condensation of water vapor, precipitation and other impurities in the valve and prevent action.
6.Common type solenoid valve, not in regard to the use of dangerous occasions.
7.The lack of rigid pipe, valve before and after the proposed scaffold tubes fixed to prevent electromagnetic valve caused vibration.
8.Electromagnetic valve before and after pipeline installation manometer need to observe the pipeline pressure.

 

□ Fault Analysis and Removal Method:

Failure

Cause Analysis

Approach

Not energized movement

Power Connection access to undesirable
Changes in the supply voltage is not allowed within
Coil shorted or burn

The continuation of the power cable
Voltage adjustment within normal range
Coil replacement

Open valve when fluid can not

Pressure or fluid pressure not work
Fluid viscosity or temperature not
Spool and moving core surrounding dirt mixed with miscellaneous, impurities
Valve ago filters or plug valve hole
The use of high frequency or life expires

Adjust pressure or pressure or replacement of suitable products
Suitable replacement products
Internal cleansing, valve must be installed before filtration valve
Timely cleaning filters or valve hole
Model reelected or replaced with new products

Valve fluid can not cut off

Inconsistent with fluid viscosity
Fluid temperature not meet
Spring deformation or life expires
Seat adhesion defects or stolen goods
Gasket emerge ` Defects or deformation
Balance hole or orifice plug
The use of high frequency or life expires

Suitable replacement products
Suitable replacement products
Canada pads or replacement of spring
Cleaning, grinding or update
Update and re-assembly
Cleaning time
Model elections were changed or new products

Leakage

Pipeline Connection Loose
Pipeline Connection outside seals damage

Tighten bolts or receiver Thread
Replacement seals

Serious internal leakage

Fluid temperature not meet
I. seat with the main valve seat have impurities or defects
Valve and the main valve gaskets deformation or extrusion
Bad spring assembly, or deformation due Life
The use of high frequency

Fluid temperature adjustment or replacement
If cleaning or polishing will repair or replacement
Replacement of gaskets
Replacement of spring
Model reelected or replaced with new products

Energized when excessive noise

Loose Fasteners
Voltage fluctuations, are not allowed within
Fluid pressure or pressure unsuitable
Inconsistent with fluid viscosity
Armature pull-surface impurities

Tightening
Adjusted to within the normal range
Adjust pressure or pressure or replacement products
Suitable replacement products
Cleaning time

 


CopyRight Ruian East Valve Factory